Skip to content
Cold & Hot WaterCast Stainless SteelMax 1.6 MPa

Yoshitake GD-29S Pressure Reducing Valve for Water, Max 1.6 MPa

Yoshitake GD-29S direct-acting pressure reducing valve for cold and hot water. Features cast stainless steel body, EPDM disc, and JIS 16K FF flanged connection up to 1.6 MPa.

Yoshitake GD-29S Pressure Reducing Valve for Water, Max 1.6 MPa

Yoshitake GD-29S is a direct-acting pressure reducing valve designed for cold and hot water applications. Featuring a cast stainless steel body and EPDM diaphragm and valve disc, it provides excellent corrosion resistance and durability. The GD-29S supports inlet pressures up to 1.6 MPa and offers a maximum pressure reduction ratio of 10:1, making it highly reliable for stable pressure control.

INFO

The GD-29S is connected via JIS 16K FF flanged ends. A built-in strainer (40 mesh) is incorporated in sizes 20A to 50A, while sizes 65A to 100A do not include a strainer.

Features

  • Wetted parts are made of corrosion-resistant material to prevent rusty water.
  • Reduced noise operation.
  • Pressure balance structure keeps the reduced pressure at a constant level without being affected by inlet pressure fluctuations.
  • Closed structure keeps fluid inside even if the diaphragm is damaged or broken.
  • Maintenance and inspection can be conducted easily by disassembling simply from the upper side.
  • Compact and lightweight design makes piping works easy.

Specifications

SpecificationValue
ApplicationCold and hot water
Inlet pressure1.6 MPa or less
Reduced pressure(A) 0.05-0.35 MPa
(B) 0.3-0.7 MPa
Minimum differential pressure0.05 MPa
Maximum pressure reduction ratio10:1
Application temperature5-90℃
Body materialCast stainless steel
Valve seat materialCast stainless steel
Valve disc materialEPDM
Diaphragm materialEPDM
ConnectionJIS 16K FF flanged

Dimensions and Weights

Yoshitake GD-29S dimensions

Nominal sizeL (mm)H (mm)H1 (mm)Weight (kg)
20A160170413.9
25A160170414.8
32A200224578.0
40A200224578.3
50A220239.56110.8
65A2203297720.6
80A2343458225.0
100A2784129436.5

Rated Flow Rate

(The differential pressure before and after the valve is 0.15 MPa or more.)

Nominal size20A25A32A40A50A65A80A100A
Rated flow (L/min)4060100150250300450700

If the differential pressure before and after the valve is less than 0.15 MPa, select a proper nominal size from the charts below.

Flow Rate Charts

Nominal size: 20A to 50AYoshitake GD-29S flow rate chart 20A to 50A

Nominal size: 65A to 100AYoshitake GD-29S flow rate chart 65A to 100A

Performance Characteristics

Pressure Characteristic ChartYoshitake GD-29S pressure characteristic chart This chart shows variation in reduced pressure when the inlet pressure of 0.6 MPa is changed between 0.15 MPa and 1.0 MPa while the reduced pressure is set at 0.1 MPa.

Flow Characteristic ChartYoshitake GD-29S flow characteristic chart

Offset Pressure

Nominal sizePressure rangeReduced pressure rangeOffset pressure
20A-100AA0.05-0.35 MPaWithin 0.05 MPa
20A-100AB0.30-0.70 MPaWithin 0.10 MPa