Yoshitake DP-18C is a high-performance normally opened diaphragm-type solenoid valve featuring a stainless steel body, AC coil, and JIS 10K FF flanged connection for air, water, and oil.

Yoshitake DP-18C is a high-performance, normally opened diaphragm-type solenoid valve featuring a stainless steel body and flanged connections. It is designed for reliable control of applications involving air, cold and hot water, and oil. The valve utilizes an AC coil and ensures zero valve seat leakage.


| Specification | Value |
|---|---|
| Application | Air, Cold and hot water, Oil (20 cSt or less) |
| Working pressure | 0-1.0 MPa (unusable under vacuum) |
| Min. differential pressure | 0 MPa (0.1 MPa or more is required for vertical installation) |
| Valve seat leakage | No (by confirming pressure gauge visually) |
| Max. temperature | 60°C |
| Operation | Normally opened |
| Material (Body) | Stainless steel |
| Material (Valve) | NBR (diaphragm) |
| Connection | JIS 10K FF flanged |
INFO
| Specification | Value |
|---|---|
| Rated voltage | AC100/200V or AC110/220V (50/60 Hz common) |
| Voltage fluctuation tolerance | Rated voltage ±10% |
| Rated current | 0.42/0.21A (100/200V), 0.38/0.19A (110/220V) |
| Starting current | 1.64/0.82A (100/200V), 1.48/0.74A (110/220V) |
| Insulation type | Class H |
| Protection structure | Dust-proof, Splash-proof |
| Degree of protection | IP64 |
| Insulation resistance | More than 50MΩ / 500V megger |
| Anti-voltage test | 1500V/min |
The following dimensions apply to the DP-18C (normally opened, flanged type).
| Nominal size | L (mm) | H (mm) | H1 (mm) | Weight (kg) |
|---|---|---|---|---|
| 15A | 120 | 205 | 47.5 | 2.9 |
| 20A | 130 | 212 | 50.0 | 3.5 |
| 25A | 145 | 228 | 62.5 | 5.0 |
| 32A | 160 | 255 | 67.5 | 6.8 |
| 40A | 170 | 261 | 70.0 | 7.5 |
| 50A | 195 | 276 | 77.5 | 10.2 |
::: note DP-18 series uses a welding flanged structure. :::
For Air
When selecting the nominal size of a solenoid valve whose inlet pressure (P1), outlet pressure (P2), and air (20°C) flow rate (Q) are 0.5 MPa, 0.35 MPa, and 600 m³/h (standard condition), respectively, first find intersection point (a) of P1 = 0.5 MPa and P2 = 0.35 MPa. Trace down vertically from this intersection point (a) to find intersection point (b) with Q = 600 m³/h (standard condition). Since this intersection point (b) lies between nominal sizes 20A and 25A, select the larger one, 25A.
For Water
When selecting the nominal size of a solenoid valve whose inlet pressure (P1), outlet pressure (P2), and flow rate (V) are 0.7 MPa, 0.5 MPa, and 300 L/min, respectively, first find intersection point (a) of the differential pressure across the valve [ΔP = 0.7 - 0.5 = 0.2 MPa] and V = 300 L/min. Since this intersection point (a) lies between nominal sizes 25A and 32A, select the larger one, 32A.