The BURKERT 17841 (Type 0131) is a direct-acting 3/2-way toggle valve designed for reliable fluid control. Thanks to the diaphragm separation between the actuator and the valve body, aggressive media can also be safely controlled. The solenoids are moulded with a highly resistant chemical epoxy, ensuring durability in demanding environments. This specific model features a brass body, FKM (Fluor rubber) seals, a 15 mm orifice, and G 1/2 internal thread connections. "Kick and drop" electronics are moulded into the 24V DC solenoid variant for significantly reduced electrical power consumption. It also includes a robust, service-friendly manual override with a locking function.

General Technical Data ​

PropertyValue
Duty cycle100 % continuous operation
Switching frequencyMax. 6/min with UC
Switching timeOpening: 10...20 ms / Closing: 40...60 ms
Operating voltage24 V (DC/AC)
Power consumption (UC)Inrush: 100 W / Hold: 9 W
Voltage tolerance±10 %
Medium temperature (Brass/FKM)-10 °C...+90 °C (with kick and drop electronics)
ViscosityMax. 37 mm²/s
Degree of protectionIP65 with cable plug
Installation positionAny, preferably actuator face up
Ambient temperatureMax. +50 °C

Circuit Function ​

This model operates with Circuit Function C (CF C).

BURKERT 17841 Type 0131 circuit function C normally closed symbol

Circuit function C (CF C): 3/2-way solenoid valve, direct-acting, normally closed. Inlet port 1 (P/NC), outlet port 2 (A/OUT) connected with exhaust port 3 (R/NO).

Materials (3/2-way Brass Variant) ​

BURKERT 17841 Type 0131 3/2-way brass variant material diagram

No.ElementMaterial
1CoilEpoxy
2PlungerStainless steel 1.4105
3Toggle pinPTFE
4O-ringFKM (for SKU 17841)
5Closing bodyFKM (for SKU 17841)
6HousingBrass
7O-ringFKM (for SKU 17841)
8Lateral flangePC
9Manual overrideWith locking function

Dimensions ​

BURKERT 17841 Type 0131 3/2-way brass variant dimensions drawing

Note: Dimensions in mm.

MaterialDNConnectionDL
Brass10ThreadedG 3/812
Brass15ThreadedG 1/214
Brass20ThreadedG 3/416

Installation and Safety ​

Risk of injury from high pressure

Before loosening lines or valves, switch off the pressure and vent the lines.

Risk of injury from electric shock

Before working on the device or the system, switch off the power supply and secure against reactivation. Observe any applicable accident prevention and safety regulations for electrical devices.

Preparatory Work ​

  • Clean pipelines of any contamination.
  • Install a dirt trap upstream of the valve inlet (≤ 500 µm).
  • The valve body must not be installed under tension.
  • Pay attention to flow direction: The arrow or letters on the body indicate the flow direction: from P → A (NC).

Manual Override ​

BURKERT 17841 Type 0131 manual override operation

Escaping medium due to loss of O-rings

Loss of O-rings leads to valve leakage. Medium may escape.

When the manual override is locked, the valve can no longer be electrically actuated. To override the valve manually, press the manual override and turn it 90° clockwise until it stops.

Electrical Connection ​

Protective Conductor

If there is no protective conductor function between the coil and the body, there is a risk of electric shock. Always connect the protective conductor and check electrical continuity.

  • Observe the voltage and current type according to the type label.
  • Screw the cable plug tight, ensuring a maximum torque of 1 Nm.
  • Check that the valve seal is correctly seated.