Yoshitake DP-14C is a flanged, normally opened, AC coil diaphragm solenoid valve with a bronze body. Ideal for air, water, and oil applications up to 1.0 MPa.

Yoshitake DP-14C is a diaphragm-type solenoid valve belonging to the RED MAN ultra-high performance series. It is configured as a normally opened, AC coil valve with JIS 10K FF flanged connections and features a robust bronze body with an NBR diaphragm. The valve is designed for use with air, cold and hot water, and oil (20 cSt or less) at working pressures up to 1.0 MPa and temperatures up to 60°C. The DP-14C supports both horizontal and vertical installation and ensures zero valve seat leakage.
| Voltage and operation | AC voltage | AC voltage | DC voltage | DC voltage |
|---|---|---|---|---|
| Type | Normally closed | Normally opened | Normally closed | Normally opened |
| Screwed type | DP-16 | DP-12C, DP-16C | DP-12D, DP-16D | DP-12CD, DP-16CD |
| Flanged type | DP-18 | DP-14C, DP-18C | DP-14D, DP-18D | DP-14CD, DP-18CD |


| Model | AC coil / DC coil | Application | Working pressure | Min. differential pressure | Valve seat leakage | Max. temperature | Operation | Body Material | Valve Material | Connection |
|---|---|---|---|---|---|---|---|---|---|---|
| DP-12C / DP-14C | AC coil | Air, Cold and hot water, Oil (20 cSt or less) | 0-1.0 MPa (unusable under vacuum) | 0 MPa (0.1 MPa or more for vertical) | No | 60°C | Normally opened | Bronze | NBR (diaphragm) | JIS Rc screwed (12C) / JIS 10K FF flanged (14C) |
| DP-12D / DP-14D | DC coil | Air, Cold and hot water, Oil (20 cSt or less) | 0-1.0 MPa (unusable under vacuum) | 0 MPa (0.1 MPa or more for vertical) | No | 60°C | Normally closed | Bronze | NBR (diaphragm) | JIS Rc screwed (12D) / JIS 10K FF flanged (14D) |
| DP-12CD / DP-14CD | DC coil | Air, Cold and hot water, Oil (20 cSt or less) | 0-1.0 MPa (unusable under vacuum) | 0 MPa (0.1 MPa or more for vertical) | No | 60°C | Normally opened | Bronze | NBR (diaphragm) | JIS Rc screwed (12CD) / JIS 10K FF flanged (14CD) |
Stainless Steel Models
For stainless steel body models, refer to the DP-16 and DP-18 series.
| Rated voltage | AC100/200V, AC110/220V | DC24V |
|---|---|---|
| Voltage fluctuation tolerance | Rated voltage ±10% | Rated voltage ±10% |
| Rated current | 0.42/0.21A (AC100/200V), 0.38/0.19A (AC110/220V) | 1.13A |
| Starting current | 1.64/0.82A (AC100/200V), 1.48/0.74A (AC110/220V) | - |
| Insulation type | Class H | Class H |
| Protection structure | Dust-proof, Splash-proof | Dust-proof, Splash-proof |
| Degree of protection | IP64 | IP64 |
| Insulation resistance | More than 50MΩ / 500V megger | More than 50MΩ / 500V megger |
| Anti-voltage test | 1500 V/min | 1500 V/min |
| Nominal size | d | L | H | H1 | Weight (kg) |
|---|---|---|---|---|---|
| 15A | 15 | 120 | 205 | 47.5 | 2.9 |
| 20A | 20 | 130 | 212 | 50.0 | 3.5 |
| 25A | 25 | 145 | 228 | 62.5 | 5.0 |
| 32A | 32 | 160 | 255 | 67.5 | 6.8 |
| 40A | 40 | 170 | 261 | 70.0 | 7.5 |
| 50A | 50 | 195 | 276 | 77.5 | 10.2 |
Note: The DP-18 series is slightly heavier and uses a welding flanged structure.

How to use the chart: When selecting the nominal size of a solenoid valve whose inlet pressure (P1), outlet pressure (P2), and air (20°C) flow rate (Q) are 0.5 MPa, 0.35 MPa, and 600 m³/h (standard condition), respectively, first find intersection point (a) of P1 = 0.5 MPa and P2 = 0.35 MPa. Trace down vertically from this intersection point (a) to find intersection point (b) with Q = 600 m³/h. Since this intersection point (b) lies between nominal sizes 20A and 25A, select the larger one, 25A.
How to use the chart: When selecting the nominal size of a solenoid valve whose inlet pressure (P1), outlet pressure (P2), and flow rate (V) are 0.7 MPa, 0.5 MPa, and 300 L/min, respectively, first find intersection point (a) of differential pressure (ΔP = 0.7 - 0.5 = 0.2 MPa) and V = 300 L/min. Since this intersection point (a) lies between nominal sizes 25A and 32A, select the larger one, 32A.