Skip to content
Explosion-proofATEXIECExIP65Direct-acting

BURKERT 366334 Burkert Type 0330 3/2-Way Direct-Acting Solenoid Valve Ex

Burkert Type 0330 (SKU 366334) is a 3/2-way direct-acting explosion-proof solenoid valve. Features stainless steel body, NPT 1/4 connection, FKM seal, 24V operation, and ATEX/IECEx approvals.

BURKERT 366334 Burkert Type 0330 3/2-Way Direct-Acting Solenoid Valve Ex

Burkert Type 0330 (SKU 366334) is a direct-acting, media-separated pivoted armature solenoid valve. This specific explosion-proof variant features a stainless steel body, FKM (fluor rubber) seals, and an NPT 1/4 internal thread connection. It operates at 24 V with a 3-meter wire cable electrical connection and is designed for universal use (Circuit Function T). The coil system is separated from the medium by a diaphragm, making it suitable for critical media such as aggressive acids and alkalis.

Burkert 366334 Type 0330 solenoid valve family

General Technical Data ​

PropertySpecification
OrificeDN 3.00 mm
Circuit functionT (3/2-way, universal use)
Body materialStainless steel (1.4401)
Seal materialFKM (Fluor rubber)
Port connectionNPT 1/4
Voltage24 V
Pressure range0.00 - 6.00 bar
Medium temperature0 °C to +90 °C
Ambient temperatureMax. +55 °C
Degree of protectionIP65
Electrical connectionWire cable (3,000 mm)

Circuit Function ​

SymbolDescription
Burkert 366334 Type 0330 circuit function T diagramCircuit function T (CF T)
3/2-way solenoid valve
Direct-acting
Flow direction optional
Normally closed

Explosion Protection Approvals ​

ATEX and IECEx Certifications

This valve is an explosion-proof variant with the following markings for coils with cable outlet:

  • ATEX: EPS 16 ATEX 1 111 X, II 2G Ex mb IIC T4 Gb, II 2D Ex mb IIIC T130 °C Db
  • IECEx: IECEx EPS 16.0049X, Ex mb IIC T4 Gb, Ex mb IIIC T130 °C Db

Materials ​

ElementMaterial
CoilEpoxy
Diaphragm / O-ringFKM
Seat / Valve bodyStainless steel (1.4401)

Dimensions ​

Explosion-proof Cable Variant

Burkert 366334 Type 0330 explosion-proof cable variant dimensions

Note: Dimensions in mm. For NPT thread, D2 = NPT 1/4 and L2 = 7.5 mm.

Product Connections ​

Pin Assignment Explosion-proof Variant

The pin assignment depends on the circuit function. For Circuit Function T, the connections are as follows:

Circuit functionConnection 1Connection 2Connection 33-way Diagram
TNCIN/OUTNOBurkert 366334 Type 0330 pin assignment for explosion-proof variant

Safety Instructions ​

Risk of injury from high pressure

  • Before working on equipment or device, switch off the pressure and deaerate/drain lines.

Risk of injury from electric shock

  • Before working on the system or device, switch off the power supply and secure against reactivation.
  • Observe the applicable accident prevention and safety regulations for electrical devices.

Risk of burns or fire

  • The solenoid valve can become very hot during continuous operation. Keep the device away from highly flammable substances and media and do not touch with bare hands.