Skip to content
3/2-wayNormally OpenServo-assistedIP65

BURKERT 357601 Burkert Type 6430 3/2-Way Servo-Assisted Solenoid Valve, Normally Open, G 1/4, 24V DC

Burkert 357601 (Type 6430) is a 3/2-way servo-assisted piston solenoid valve. Features normally open (NO) function, G 1/4 internal thread, brass body, NBR seal, 24V DC, and 1-16 bar pressure range.

BURKERT 357601 Burkert Type 6430 3/2-Way Servo-Assisted Solenoid Valve, Normally Open, G 1/4, 24V DC

BURKERT 357601 (Type 6430) is a servo-assisted 3/2-way piston valve. If the valve is not supplied with auxiliary pilot air, a minimum differential pressure is required for the function. This specific model features a normally open (NO) circuit function, G 1/4 internal thread, brass body, and NBR seals, operating at 24V DC within a pressure range of 1 to 16 bar.

The Type 6430 is equipped with a manual override for start-up or manual operation. To reduce electrical power consumption during operation, it utilizes a maintenance-free, media-separated 3/2-way pivoted armature valve Type 0331 as a pilot valve. In combination with a plug to DIN EN 175301 – 803 Form A, the valve satisfies degree of protection IP65.

Technical Data ​

PropertyValue
Orifice8.0 mm
Port ConnectionG 1/4 Internal thread
Circuit FunctionD (Normally Open)
Pressure Range1.0 - 16.0 bar
Kv Value Water0.95 m³/h
Voltage24 V DC
Body MaterialBrass
Seal MaterialNBR
Weight0.9 kg
Medium Temperature0 °C to +80 °C
Ambient Temperature0 °C to +55 °C
ViscosityMax. 21 mm²/s (21 cSt)

Circuit Function ​

BURKERT 357601 circuit function D normally open

Circuit function D (CF D): 3/2-way solenoid valve, servo-controlled, with manual override, normally open.

Material Specifications ​

BURKERT 357601 material specifications diagram

No.ElementMaterial
1CoilEpoxy
2O-ringNBR
4Piston ringPTFE
5HousingBrass
6Seat sealNBR
7Piston sealNBR
8SealNBR
9DiaphragmNBR
10Manual overridePA

Dimensions ​

INFO

Dimensions in mm. The figure shows the valve in circuit function C with ports P, R and A/B (manual override via port P). In circuit function D, the manual override is located above port A/B.

BURKERT 357601 dimensions diagram

DNA1B1CDE1F1GHJKLMNO
8G 1/41234.5SW22G 3/812SW22233076546124.833

Installation ​

Risk of injury from high pressure and electric shock

  • Before loosening lines and valves, switch off the pressure! Vent or empty the lines.
  • Before working on the device or system, switch off the power supply. Secure against reactivation.
  • Observe the applicable accident prevention and safety regulations for electrical devices.

Before installation:

  • Check pipelines for soiling and clean if required.
  • Install a dirt trap upstream of the valve inlet (≤ 500 µm).

Installation:

  • Any installation position, preferably actuator face up.
  • Ensure that the valve body is not installed twisted.
  • Ensure that seal material does not get into the device.
  • Hold the device on the body using an open-end wrench and screw into the pipeline. Do not use the solenoid as a lever arm.

Manual Override

When manual override is locked, the valve can no longer be electrically actuated.

Maintenance and Troubleshooting ​

WARNING

Maintenance may be carried out by authorised technicians only and with the appropriate tools. Secure the system against unintentional activation.

Valve does not switch:

  • Short-circuit or coil interrupted
  • Inadequate power supply
  • Interior of the valve soiled
  • Medium pressure outside the permitted pressure range
  • Manual override locked
  • Not enough differential pressure available

Valve does not close:

  • Interior of the valve soiled
  • Manual override locked
  • Not enough differential pressure available