Skip to content
Bronze10K20K

Yoshitake BLV-1 Bronze Ball Valve, 4.12 MPa

Yoshitake BLV-1 bronze ball valve with chrome-plated brass or stainless steel ball. Suitable for steam, air, water, and oil up to 4.12 MPa.

Yoshitake BLV-1 Bronze Ball Valve, 4.12 MPa

Yoshitake BLV-1 is a bronze ball valve equipped with a chrome-plated brass or stainless steel ball. It is widely applicable for fluid media such as steam, air, water, and oil. The valve is supplied in a closed position at the time of shipment from the factory, and there is no restriction on flow direction.

Specifications

ApplicationSteam, Air, Cold and hot water, Oil, Other non-dangerous fluids
Maximum pressureSaturated steam: 1.0 MPa
Water, oil, air or other non-dangerous fluid at 40°C or lower: 4.12 MPa
Material (Body)Bronze
Material (Ball)Cr plated brass or stainless steel
Material (Stem)Brass
ConnectionJIS Rc screwed

Dimensions and Weight

Nominal sized1dLHWWeight (kg)
8ARc 1/41049471060.2
10ARc 3/81049471060.2
15ARc 1/212.753471060.3
20ARc 3/41556521060.3
25ARc 12068551060.5
32ARc 1-1/42586661360.8
40ARc 1-1/231.896721361.2
50ARc 238108811361.8

Yoshitake BLV-1 dimensions and weight

Parts and Materials

No.Name of PartsMaterialQty
1BodyBronze1
2CapBronze1
3BallBrass + Chrome plate or Stainless Steel1
4StemDZR1
5HandleSteel + PVC1
6Gland PackingPTFE1
7Washer of PackingBrass1
8Ball seatPTFE2
9NutSteel1

Yoshitake BLV-1 structural drawing

Operation and Maintenance

WARNING

Before applying fluid, make sure that there is no danger if the fluid flow into the end of the piping. Failure to follow this notice may result in property damage due to fluid leakage.

Completely discharge the pressure inside of the product, line and equipment before inspection and maintenance. For high temperature fluid, cool down the product til it can be touched with bare hands. Failure to follow this notice may result in injury or burns due to residual pressure.

Storage and Installation

  • Store the product indoors in a dust free, low humidity, dry and ventilated environment.
  • Installation should be conducted by suitably trained personnel, wearing protective head, eye, hand and foot protection.
  • The product can be used for "complete opening" and "complete closing". If the product is used at intermediate opening, ball and ball seat may be damaged.
  • Be careful that the threaded connection between the mating pipe and the internal threaded connections of the valves are in line to avoid piping stresses in the valves.
  • During transportation or storage of the product leakage may occur from the washer of packing due to decreasing of tightening pressure by stress relaxation of the packing. Be sure to retighten the washer of packing before use.

Periodic Inspection

Please conduct periodic inspection about once a year in order to maintain optimal performance and function of the product.

  • Opening and closing operation
  • Abnormal sound
  • Outside leakage

Troubleshooting

TroubleCauseRemedy
Outside leakage1. Tightening of the washer of packing is loosened.
2. The gland packing is damaged.
3. The spindle is damaged.
1. Tighten the washer of packing additionally.
2. Replace the product with new one.
3. Replace the product with new one.
Leakage from the ball part on complete closing1. The ball and/or ball seat is damaged.
2. Foreign substance is stuck.
1. Replace the product with new one.
2. Remove the foreign substance.
Operation torque of the handle is abnormally large1. Too much tightening of the washer of packing.
2. Foreign substance is stuck on spindle and screw part.
1. Loosen the washer of packing and tighten it again to the no leakage degree.
2. Remove the foreign substance.
Abnormal sound1. Each screw part is loosened.1. Retighten the loosened parts.