The TLV GP10 PowerTrap is a mechanical pump designed to discharge condensate from vacuum or low-pressure areas to high-pressure areas in open and closed systems.

TLV GP10 PowerTrap is used to discharge liquid from vacuum-pressure or low-pressure areas to high-pressure areas, or from lower to higher elevations. It is a mechanical pump operated by steam, compressed air, or nitrogen.
WARNING
Install properly and DO NOT use this product outside the recommended operating pressure, temperature and other specification ranges. Improper use may result in such hazards as damage to the product or malfunctions which may lead to serious accidents.
There are two types of delivery systems: the closed system and the open system. Use of the GT model or the GP model is determined by the type of system.
| Type of System | Closed System | Open System |
|---|---|---|
| Benefits | No need for external steam trap (GT model features built-in trap). No flash steam discharge. Small reservoir. Use with vacuum equipment possible. | Collection of condensate from multiple equipment possible. Can be used where trap is lower than receiver. Separate steam trap required for each piece of equipment. |
| Notes | Only one piece of equipment possible per system. Equipment has minimum height requirement to ensure gravity flow (approx. 1 m (40 in)). | |
| GP10/GP14 | Can be used where there is ALWAYS a negative pressure differential (e.g., vacuum equipment) | Mechanical pump |
| GT10/GT14 | Mechanical pump with built-in trap |
DANGER
Take measures to prevent people from coming into direct contact with product outlets. Failure to do so may result in burns or other injury from the discharge of fluids.

| Specification | GP10/GT10 |
|---|---|
| Motive Medium Pressure Range | 0.03 to 1.05 MPaG (0.3 to 10.5 barg, 5 to 150 psig) |
| Maximum Allowable Back Pressure | 0.05 MPa (0.5 bar, 7 psi) less than motive medium pressure used |
WARNING
Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are PRESSURE SHELL DESIGN CONDITIONS, NOT OPERATING CONDITIONS.


It is necessary to install a condensate receiver for storing condensate during pumping. Condensate cannot enter the PowerTrap while condensate is being pumped.

In closed system applications, the motive medium must be compatible with the liquid being pumped. If a non-condensable gas such as air or nitrogen is used as the motive medium, please consult TLV for assistance.
The exhaust pipe diameter should be at least 25 mm (1 in) and connected to the top of the receiver/reservoir.
For Open Systems: If the GP exhaust line has to discharge to atmosphere, a sound level of approximately 90 to 100dB (GP10) may be emitted. Make sure the distance from the ground to the highest point on the exhaust pipe does not exceed 3 m (10 ft). If it exceeds 3 m and steam is used as the motive medium, condensate must be drained from the exhaust pipe.