Skip to content
Manual ActuatorStainless Steel 316LPTFE Seat SealPN 25 / Class 150

BURKERT 20110610 Type 2920 Manual 2/2-Way Angle Seat Valve

BURKERT Type 2920 manual 2/2-way angle seat valve (SKU 20110610). Features a flow-optimised stainless steel body, PTFE seat seal, and robust plastic actuator. Supports 0-24 bar and -10°C to 185°C.

BURKERT 20110610 Type 2920 Manual 2/2-Way Angle Seat Valve

BURKERT Type 2920 (SKU 20110610) is a manually operated 2/2-way angle seat valve consisting of a manual actuator and a 2-way body made of high-quality stainless steel. With a flow-optimised valve body, the manually operated valve offers diverse usage options to shut off both neutral and aggressive gaseous and liquid media. The tried-and-tested self-adjusting packing gland guarantees optimal tightness and enables low-maintenance operation, even at high switching cycles. Depending on the application, the soft PTFE or PEEK seal ensures a reliable valve seat seal under challenging operating conditions.

The actuator is made of high-quality plastic (Polyphenylene sulfide) and is suitable for use in demanding environments. It possesses a visual position indicator and can be optionally equipped with stroke limitation and locking.

Product Variants ​

The product family includes Types 2920, 2921, 2960, and 2961, which differ by valve body design and the presence of a control cone.

TypeNominal diameter DNValve bodyProperties
292010 to 80Angle seat bodyWithout control cones; for pure shut-off function
296010 to 65Angle seat bodyWith control cone; with position indicator and scale to set a defined flow rate
292110 to 100Globe bodyWithout control cones; for pure shut-off function
296110 to 100Globe bodyWith control cone; with position indicator and scale to set a defined flow rate; with screwed-in valve seat that can be replaced to reduce the seat size

BURKERT 20110610 BURKERT Type 2920 2/2-way angle seat valve with manual actuator

BURKERT 20110610 BURKERT Type 2921 2/2-way globe valve with manual actuator

General Technical Data ​

PropertyValue
DesignAngle seat valve on/off
Nominal diameterDN 10...DN 80, NPS 3/8...NPS 3
Flow directionFlow to open (below seat)
Operating pressure0 bar(g)...25 bar(g)
Nominal pressurePN 25 (DIN EN 1333), Class 150 (DIN EN 1759)
Seat leakageLeakage rate A (DIN EN 12266-1), seat seal PTFE and PEEK, test medium air
Operating mediumSteam, water, neutral gases, alcohols, oils, fuels, hydraulic fluids, salt solutions, alkalis, organic solvents
Medium temperature-40 °C...+230 °C
Ambient temperature-10 °C...+60 °C
ViscosityMax. 600 mm²/s
Installation positionAs required, preferably with actuator upright

Material Specifications ​

ElementMaterial
CoverPolyamide (PA)
ScrewStainless steel 1.4301
Lock pinStainless steel 1.4305
HandwheelPolyphenylene sulfide (PPS)
Optical position indicatorPolyamide (PA)
Packing glandPTFE V-rings (filled), with spring compensation
SpindleStainless steel 1.4401 (316)/1.4404 (316L)
Spindle guideDN 15...DN 50: PEEK; DN 65...DN 80: Stainless steel 1.4401 (316)/1.4404 (316L)
Body sealGraphite
Swivel plateStainless steel 1.4401 (316)/1.4404 (316L)
Seat sealPTFE or PEEK
Valve bodyStainless steel 316L/CF3M

Approvals and Conformities ​

  • Pressure Equipment Directive: 2014/68/EU.
  • Explosion Protection (Optional): ATEX (EPS 18 ATEX 2 008 XII 2G Ex h IIC T4...T2 Gb / II 2D Ex h IIIC T135 °C...T300 °C Db) and IECEx (IECEx EPS 18.0007X). Suitable for zone 1/21 and zone 2/22 as a category 2 device.
  • Drinking Water: Suitable for use in drinking water applications. Materials comply with the assessment principles (UBA) for materials in contact with drinking water (TrinkwasserV).
  • Foods and Beverages/Hygiene: FDA Code of Federal Regulations, United States Pharmacopeial Convention (USP), EC Regulation 1935/2004, and China food GB Standards.

Function and Features ​

By manually overriding the handwheel, the force is transmitted via a spindle and the valve is opened or closed. Turning the handwheel anticlockwise opens the valve, turning it clockwise closes it.

Position Indicator ​

When turning the handwheel anticlockwise, the reproducible stroke scale becomes visible between the position indicator and the handwheel. The scale on the handwheel determines the rotation position of the handwheel (50 positions). The reproducible stroke scale shows the relative position of the valve (valve opening) and acts as a fixation point for determining the rotation position.

BURKERT 20110610 BURKERT Type 2920 position indicator with reproducible stroke scale

INFO

The visibility of the stroke scale is not directly correlated with the closed position of the valve. Depending on the valve design, the repeatable stroke scale may not be visible when the valve is open, or be visible when the valve is closed.

Flow Direction ​

The valve seat is always closed against the medium flow. The flow direction should therefore be set such that the valve reaches the flow beneath the valve seat.

BURKERT 20110610 BURKERT Type 2920 flow direction below seat

Stroke Limitation (Optional) ​

Setting the minimum and maximum stroke limit is possible as an option. An adjusting sleeve is used for this purpose. Both the minimum and the maximum position of the valve can be adjusted via an adjustment sleeve after removing the handwheel.

BURKERT 20110610 BURKERT Type 2920 stroke limit adjustment sleeve

Lock Handwheel (Optional) ​

It is also an option to lock the handwheel to prevent unintentional or unauthorised operation of the valve. The locking pin has a bore (Ø 3.8) and can be secured against unauthorised use with a padlock.

BURKERT 20110610 BURKERT Type 2920 handwheel locking mechanism

Installation and Maintenance ​

WARNING

Risk of injury due to high pressure and escaping medium Switch off the pressure before working on the device or system. Vent or drain the lines.

WARNING

Risk of crushing by mechanically powered parts Do not reach into the openings of the valve body.

When used in accordance with the operating instructions, the actuator of the manually operated valve is maintenance-free. Perform a visual inspection of the device once per year. If leaks occur, replace the respective wearing part. Muddy and abrasive media require correspondingly shorter inspection intervals.

Troubleshooting ​

TroubleshootingCauseElimination
Valve is not tightDirt between seal and valve seatInstall dirt trap
Valve seat seal wornInstall new control cone
Flow direction interchangedObserve the marking for the flow direction on the valve body
Operating pressure too highObserve pressure specifications on the type label
Valve is leaking on the relief borePacking gland wornReplacing packing gland